Use this form to record the conditions, observations and results of differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) performed on polymers, chemicals and other materials. Complete each field as accurately as possible and leave a field blank rather than guessing. Terminology, units and thresholds should follow whatever internal conventions your organisation uses.
Report or record reference number
Study or project title
Date of analysis
Requesting department, team or client
Requesting person and contact e-mail
Lead analyst or operator
Laboratory or testing facility
Priority of this analysis
Routine queue
Expedited
Research/exploratory
Repeat or confirmation run
Comparative study
Number of samples included in this batch
Quotation or internal cost recorded for this analysis (optional)
Sample ID
Sample name or designation
Material class
Polymer or elastomer
Chemical/organic compound
Inorganic material or mineral
Composite or filled system
Coating, adhesive or sealant
Pharmaceutical material or excipient
Food or biological-derived material
Other
Supplier, manufacturer or source
Batch, lot or synthesis number
Date sample was received or drawn
Physical form of the sample as received
Granules
Powder
Film or sheet
Fibre
Pellet
Solid block or machined part
Liquid or solution
Paste or gel
Coated substrate
Other
Colour and visual appearance
Photograph of the sample as received (optional)
Is the composition or purity of the sample documented?
Does the sample have a known thermal or processing history?
Has any pre-test drying or conditioning been performed?
Approximate sample mass available for testing (mg)
Are any hazard, handling or safety notes available for this sample?
Safety data sheet, certificate of analysis or composition report (optional)
Select every technique applied to this sample. Follow-up questions will ask for the settings that most strongly influence each measurement.
Technique(s) performed
Differential scanning calorimetry (DSC)
Modulated or alternating-temperature DSC
Thermogravimetric analysis (TGA)
Simultaneous thermal analysis (combined TGA + DSC)
TGA coupled to evolved gas analysis
Hot-stage microscopy or thermomicroscopy
Other thermal technique
Primary objective of the analysis
Material identification or fingerprinting
Incoming/outgoing quality control
Melting or softening characterisation
Glass transition characterisation
Thermal stability or decomposition screening
Moisture, volatiles or solvent content
Oxidative stability assessment
Method development or troubleshooting
Comparative study against reference material
Reference standard, published method or internal procedure cited
Was the referenced method followed exactly as written?
Method version, revision or date of the procedure used
Instrument reference/asset ID
Instrument type, manufacturer and model (as recorded in your asset register)
Serial number and control software version
Date of most recent calibration or verification
Calibration or verification reference used
Did the calibration or system suitability check fall within the expected range on the day of testing?
Sample pan/crucible type
Sealed or hermetic pan
Open pan
Pierced/vented lid
High-pressure pan
Platinum or metal crucible
Ceramic/alumina crucible
Other
Reference or empty pan/crucible details
Gas flow rate through the cell (mL/min)
Was the instrument cell purged and equilibrated before loading the sample?
These parameters drive nearly every thermal result reported below. Record measured values rather than target values wherever possible.
Sample mass used in the run (mg)
Heating rate (°C per minute)
Start temperature of the measured range (°C)
End temperature of the measured range (°C)
Isothermal hold at the start (minutes)
Isothermal hold at the end or between steps (minutes)
Cooling rate applied in a cool or reheat segment (°C per minute)
Furnace/cell atmosphere during the measurement
Inert (e.g. nitrogen)
Inert (e.g. argon)
Inert (e.g. helium)
Air/synthetic air
Oxygen-enriched
Vacuum or reduced pressure
Gas mixture
Switched mid-run from inert to oxidative
Purge gas flow rate at the balance (mL/min), if separately controlled
Temperature programme as executed
Segment number | Step type | From temperature (°C) | To temperature (°C) | Rate (°C/min) | Hold time (min) | Temperature span (°C) | |
|---|---|---|---|---|---|---|---|
1 | Isothermal equilibration | -50 | -50 | 0 | 5 | 0 | |
2 | Heating ramp (first heat) | -50 | 250 | 10 | 0 | 300 | |
3 | Cooling ramp | 250 | -50 | 10 | 0 | 300 | |
4 | Heating ramp (second heat) | -50 | 250 | 10 | 0 | 300 | |
Was the same heating rate used for every sample in this comparison?
Report transition values with the determination convention you used (onset, midpoint or peak) and the heating cycle in which they were observed, since first-heat and second-heat values often differ.
Was a glass transition detected?
Convention used to report the glass transition temperature
Midpoint
Onset
Inflection point
Endpoint
Not applicable
Was a melting event detected?
Melting onset temperature (°C)
Enthalpy of fusion (J/g)
Crystallisation temperature on cooling (°C)
Enthalpy of crystallisation (J/g)
Degree of crystallinity (%), if calculated
Was a reference enthalpy value for 100% crystallinity available?
DSC thermal events summary
Event number | Event description | Onset (°C) | Peak or midpoint (°C) | Enthalpy (J/g) | Peak minus onset (°C) | Assignment or comment | |
|---|---|---|---|---|---|---|---|
1 | Glass transition | -12 | -8 | 0 | 4 | step change in heat flow | |
2 | Melting endotherm | 158 | 164 | 92 | 6 | main melting peak | |
Were any additional thermal events observed (e.g. cold crystallisation, curing exotherm, polymorphic transitions, relaxations)?
Was a modulated or reversing/non-reversing signal split used?
Was the run repeated to check repeatability of the reported transitions?
Mass loss values are strongly affected by sample mass, particle size, heating rate, atmosphere and pan geometry. Report the values actually measured and note the atmosphere alongside any decomposition figure.
Initial sample mass recorded by the balance (mg)
Final residual mass at the end of the programme (mg)
Total mass loss across the run (%)
Residual mass or char remaining (%)
Moisture or volatile content lost before 150 °C (%), if reported separately
Decomposition onset temperature (°C)
Temperature at 5% mass loss (°C)
Temperature at 10% mass loss (°C)
Peak decomposition temperature from the derivative curve (°C)
Number of distinct mass-loss steps observed
Mass loss steps in detail
Step number | Onset (°C) | Peak/inflection (°C) | End (°C) | Mass loss in step (%) | Mass remaining after step (%) | Assignment or comment | |
|---|---|---|---|---|---|---|---|
1 | 40 | 82 | 130 | 2.1 | 97.9 | loss of adsorbed moisture | |
2 | 320 | 368 | 410 | 61.4 | 36.5 | main chain decomposition | |
Was multi-step decomposition observed?
Was the residual mass or char further characterised?
Was evolved gas information collected alongside the mass loss?
Was the balance buoyancy or baseline correction applied?
Were runs performed in both inert and oxidative atmospheres for comparison?
Oxidation onset temperature (°C), if determined
Induction or stabilisation time at a fixed isothermal temperature (minutes), if measured
Fixed isothermal temperature used for an oxidative stability test (°C)
Notes on gas purity, gas switching sequence or oxygen sensitivity during the run:
Use this section to record how far the results can be relied upon. Statements here are self-assessment by the analyst and are not an independent validation of the data.
Please rate the following aspects of the data set
Very poor | Poor | Acceptable | Good | Excellent | Not assessed | |
|---|---|---|---|---|---|---|
Baseline stability and flatness | ||||||
Peak shape and separation | ||||||
Sample homogeneity as loaded | ||||||
Signal-to-noise ratio | ||||||
Repeatability between runs | ||||||
Agreement with expected or reference behaviour |
Overall confidence in the reported values, from 1 (low) to 5 (high)
Rate how strongly each factor may have influenced the results
Sample mass used | |
Heating rate applied | |
Particle size or sample geometry | |
Atmosphere purity and flow | |
Pan or crucible choice | |
Sample thermal history | |
Moisture content of the sample |
Please rank these follow-up actions in order of priority for this material
Repeat at a slower heating rate | |
Repeat with a smaller sample mass | |
Repeat under a different atmosphere | |
Repeat with drying or conditioning step | |
Couple to evolved gas analysis | |
Repeat on a second instrument for comparison |
Were the results compared with reference, literature or previously recorded values?
Were any anomalous, unexpected or unexplained features observed?
Limitations, sources of uncertainty and conditions affecting interpretation
How satisfied are you with the overall quality of this data set?
Rate the overall completeness of the recorded information in this form
Summary of findings
Conclusion or recommendation
Recommended next steps
No further work required
Repeat measurement for confirmation
Extend the temperature range
Change atmosphere or heating rate
Perform complementary characterisation
Request additional sample
Escalate for technical review
Raw data export files (optional)
Thermogram or mass-loss curve image
Supporting calculations, calibration certificates or notes (optional)
Review status of this record
Draft — not yet reviewed
Internal technical review completed
Peer reviewed
Superseded by a later revision
Closed
I confirm that the values recorded in this form reflect the runs performed and the data obtained as observed
I understand this record documents test observations only and does not by itself certify material suitability for any particular application
Name of person signing
Date of sign-off
Signature of analyst or authorised reviewer
Analysis for Thermal Analysis Record Form — DSC & TGA Test Report Template
Important Note:
This analysis provides strategic insights to help you get the most from your form's submission data for powerful follow-up actions and better outcomes.
AI-Generated Content: This template and its accompanying guidance are AI-generated to provide a practical starting point for your form-building needs. Please review and customise the content to ensure it is accurate, appropriate and suitable for your intended use.
This guide is provided for general informational and planning purposes only. It does not constitute professional, legal, financial, medical, employment, privacy, regulatory, or advice of any other kind, nor does it certify that this template is suitable or compliant for any particular jurisdiction or purpose.
Laws, regulations, industry practices and business requirements vary. You are responsible for reviewing and customising the template to suit your intended use and obtaining advice from appropriately qualified professionals where necessary.
Please delete this section before publishing your form. See our Terms of Service for further information.
This thermal analysis record form provides a highly structured, technically thorough framework for documenting differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) performed on polymers, chemicals and other materials. The form is organised into nine logically sequenced sections — from report identification through sample characterisation, method selection, instrumentation, test conditions, DSC results, TGA results, atmosphere effects, data quality and sign-off. This progression mirrors the natural workflow of a thermal analysis experiment and helps ensure that each detail is captured at the point where it is most relevant. The form combines open-ended numeric and text fields, single- and multiple-choice selections, yes/no gates with conditional follow-ups, tables for tabulated temperature programmes and event summaries, rating scales for data quality self-assessment, and file/image upload options for supporting evidence. The design choices collectively support traceable, reproducible and well-documented thermal analysis records.
The form demonstrates several notable strengths:
Report or record reference number serves as the primary unique identifier for this record, enabling it to be indexed, cross-referenced and retrieved within a document management system. A consistent reference scheme supports auditability and prevents confusion between similar reports.
Study or project title provides human-readable context for the record. It helps reviewers, clients or colleagues quickly understand the scope and purpose of the analysis without delving into technical details.
Date of analysis anchors the record in time, which is important for correlating results with instrument calibration status, sample condition and any external events. A pre-populated default value is a thoughtful convenience.
Requesting department, team or client and Requesting person and contact e-mail provide traceability for who initiated the work and how follow-up queries can be directed. These are kept optional, which reduces barriers for internal runs where the requester context may already be known.
Lead analyst or operator identifies the person responsible for the measurement, supporting accountability and enabling technical discussions to reach the right individual.
Laboratory or testing facility records where the work was performed, which is useful when multiple sites or shared instruments are involved.
Priority of this analysis is a well-designed single-choice field with intelligent conditional follow-ups: expedited runs prompt for turnaround expectations, repeat runs prompt for the original reference, and comparative studies prompt for the comparison targets. This captures scheduling context efficiently.
Number of samples included in this batch and Quotation or internal cost recorded for this analysis (optional) support administrative tracking and resource planning. Both are optional, appropriately reflecting that cost data may not always be relevant.
Sample ID is the core identifier linking the thermal data to a physical specimen. Its mandatory status reflects its critical role in data traceability.
Sample name or designation adds a human-readable label alongside the coded ID, improving clarity for readers unfamiliar with internal naming conventions.
Material class uses a comprehensive single-choice list covering polymers, chemicals, minerals, composites, coatings, pharmaceuticals, food/biological materials and other. The conditional follow-ups for polymers (family/grade), minerals (compound and phase), composites (matrix and filler description) and other (free text) demonstrate thoughtful, context-aware design.
Supplier, manufacturer or source and Batch, lot or synthesis number enable traceability back to material origins, supporting batch comparison and supply chain investigation.
Date sample was received or drawn establishes a timeline for sample handling and condition, which can be relevant when thermal history or aging is a factor.
Physical form of the sample as received is a multiple-choice field with a follow-up for liquids/solutions asking for solvent and concentration. Physical form influences sample preparation and can affect thermal measurements, making this a practical data point.
Colour and visual appearance provides a quick qualitative reference that can aid sample identification and spot mix-ups.
Photograph of the sample as received (optional) is an excellent visual reference, reducing ambiguity about what was tested.
Is the composition or purity of the sample documented? is a well-structured yes/no gate. The yes branch asks for details and source (e.g. certificate of analysis), while the no branch prompts for unknowns and planned steps. This transparency is valuable for interpreting thermal results.
Does the sample have a known thermal or processing history? and Has any pre-test drying or conditioning been performed? both collect context that strongly influences DSC results — particularly glass transition and melting behaviour. The conditional follow-ups capture processing details and conditioning parameters.
Approximate sample mass available for testing (mg) helps plan the run and ensures sufficient material.
Are any hazard, handling or safety notes available for this sample? is a responsible inclusion. The no branch includes a checkbox confirming general laboratory precautions were applied, which is a proportionate safety acknowledgement.
Safety data sheet, certificate of analysis or composition report (optional) provides an attachment point for supporting documentation.
Technique(s) performed is a mandatory multi-select field covering DSC, modulated DSC, TGA, simultaneous thermal analysis, evolved gas coupling, hot-stage microscopy and other. The conditional follow-ups — DSC measurement mode, modulation parameters, and evolved gas detection method — demonstrate excellent depth without burdening users who select simpler techniques.
Primary objective of the analysis is another well-designed mandatory field. Nine options cover common thermal analysis goals, and conditional follow-ups capture expected values or specification limits, stability questions, or reference materials depending on the selected objective. This focuses subsequent results interpretation.
Reference standard, published method or internal procedure cited documents the methodological basis for the test. The placeholder wisely notes that recording a reference is not an endorsement.
Was the referenced method followed exactly as written? is an important quality gate. The yes branch confirms consistency of optional variations; the no branch asks for each deviation and its reason. This supports reproducibility assessment.
Method version, revision or date of the procedure used ensures the exact procedural revision is traceable.
Instrument reference/asset ID links the record to a specific instrument in the facility's register, enabling calibration history review and instrument-specific correlation.
Instrument type, manufacturer and model provides technical context — different instrument designs (heat-flux vs. power-compensation DSC, for example) can produce different baseline behaviours.
Serial number and control software version adds further specificity for instrument identification and software-related troubleshooting.
Date of most recent calibration or verification and Calibration or verification reference used are essential context for assessing whether the instrument was in a known state at the time of testing.
Did the calibration or system suitability check fall within the expected range on the day of testing? is a critical quality gate. Both branches provide meaningful follow-ups — yes captures observed values and expected range, no captures corrective actions. This is a strong data quality safeguard.
Sample pan/crucible type influences thermal contact, mass loss behaviour and potential sample containment effects. The seven-option list covers common configurations with a follow-up for other.
Reference or empty pan/crucible details supports baseline interpretation.
Gas flow rate through the cell (mL/min) and Was the instrument cell purged and equilibrated before loading the sample? capture operational details that can affect atmospheric control and measurement stability.
The introductory paragraph appropriately notes that these parameters drive nearly every thermal result and instructs users to record measured rather than target values — a valuable best-practice reminder.
Sample mass used in the run (mg) is mandatory because it directly affects peak widths, sensitivity and mass-loss percentages. The measured value is essential for data interpretation.
Heating rate (°C per minute) is mandatory and critically important — heating rate affects peak temperatures, glass transition values and decomposition onset positions. Recording the actual rate is fundamental to reproducibility.
Start temperature of the measured range (°C) and End temperature of the measured range (°C) define the measurement window. Knowing the range is essential for understanding what thermal events could and could not be detected.
Isothermal hold at the start (minutes) and Isothermal hold at the end or between steps (minutes) capture equilibration and hold durations that affect thermal history within the run.
Cooling rate applied in a cool or reheat segment (°C per minute) is relevant for heat-cool-heat DSC protocols where cooling rate affects crystallisation behaviour.
Furnace/cell atmosphere during the measurement is a mandatory single-choice field with options for inert gases, air, oxygen-enriched, vacuum, gas mixtures and mid-run switching. The follow-ups for vacuum (pressure), gas mixtures (proportions) and switching (temperatures and gases) are well-targeted.
Purge gas flow rate at the balance (mL/min), if separately controlled captures TGA-specific flow details.
Temperature programme as executed is an excellently designed table with columns for segment number, step type, from/to temperatures, rate, hold time and a computed temperature span. The four example rows demonstrate a heat-cool-heat DSC protocol. This level of detail supports full method reconstruction.
Was the same heating rate used for every sample in this comparison? prompts analysts to consider comparability — important when results from multiple samples will be compared side by side.
The introductory paragraph appropriately reminds users to report determination conventions (onset, midpoint or peak) and the heating cycle in which transitions were observed — a key technical nuance.
Was a glass transition detected? is a well-structured yes/no gate. The yes branch captures the numeric temperature; the no branch prompts for whether the transition was expected outside the range or not expected — an important distinction for interpretation.
Convention used to report the glass transition temperature captures whether the value is a midpoint, onset, inflection or endpoint. The conditional follow-up for onset prompts for a separate onset value. This is technically sound.
Was a melting event detected? follows the same pattern, with the no branch asking whether the sample was expected to melt in range or decomposes before melting.
Melting onset temperature (°C), Enthalpy of fusion (J/g), Crystallisation temperature on cooling (°C), Enthalpy of crystallisation (J/g) and Degree of crystallinity (%), if calculated provide a comprehensive set of melting and crystallisation data.
The degree of crystallinity equation displayed in mathematical notation is a helpful technical reference, and the accompanying yes/no question about reference enthalpy availability appropriately manages expectations when this value is unknown.
DSC thermal events summary is a well-designed table with columns for event number, description, onset, peak/midpoint, enthalpy, computed peak-minus-onset width, and assignment/comment. The sample rows demonstrate glass transition and melting entries effectively.
Were any additional thermal events observed? captures cold crystallisation, curing exotherms, polymorphic transitions and relaxations through a free-text follow-up.
Was a modulated or reversing/non-reversing signal split used? and Was the run repeated to check repeatability? are important quality questions. The repeatability no branch includes a checkbox acknowledging that single measurements are indicative rather than statistically characterised — a transparent and responsible provision.
The introductory paragraph correctly notes that mass loss values are affected by sample mass, particle size, heating rate, atmosphere and pan geometry — useful context for the user.
Initial sample mass recorded by the balance (mg) and Final residual mass at the end of the programme (mg) capture the raw mass data underlying all derived percentages.
Total mass loss across the run (%) and Residual mass or char remaining (%) provide the headline TGA figures.
Moisture or volatile content lost before 150 °C (%), if reported separately is a useful, practical field — separating low-temperature volatiles from main decomposition is a common analytical distinction.
Decomposition onset temperature (°C), Temperature at 5% mass loss (°C), Temperature at 10% mass loss (°C) and Peak decomposition temperature from the derivative curve (°C) collectively capture the most commonly reported thermal stability metrics.
Number of distinct mass-loss steps observed sets context for the detailed table.
Mass loss steps in detail is a thorough table with onset, peak/inflection, end, mass loss in step, mass remaining after step and assignment. The sample rows illustrate moisture loss and main chain decomposition clearly.
Was multi-step decomposition observed? prompts for the separation method and step attribution.
Was the residual mass or char further characterised? and Was evolved gas information collected alongside the mass loss? capture complementary analyses that enhance the value of the TGA record.
Was the balance buoyancy or baseline correction applied? documents whether a common data correction was used — relevant for assessing data quality.
Were runs performed in both inert and oxidative atmospheres for comparison? is a well-structured gate. The no branch appropriately limits the scope of any oxidative claims.
Oxidation onset temperature (°C), Induction or stabilisation time at a fixed isothermal temperature (minutes) and Fixed isothermal temperature used for an oxidative stability test (°C) capture oxidative stability data when measured.
Notes on gas purity, gas switching sequence or oxygen sensitivity during the run provides useful operational context.
The introductory paragraph appropriately frames this section as self-assessment rather than independent validation.
Please rate the following aspects of the data set — a matrix rating scale covering baseline stability, peak shape, sample homogeneity, signal-to-noise, repeatability and agreement with expected behaviour. The six-point scale including 'Not assessed' is well designed.
Overall confidence in the reported values, from 1 (low) to 5 (high) provides a concise, quantified self-assessment.
Rate how strongly each factor may have influenced the results — a matrix digit rating covering sample mass, heating rate, particle size, atmosphere, pan choice, thermal history and moisture content. This systematic factor-influence assessment is highly useful for understanding result sensitivity.
Please rank these follow-up actions in order of priority for this material is a practical ranking exercise that turns the analysis into actionable next steps.
Were the results compared with reference, literature or previously recorded values? and Were any anomalous, unexpected or unexplained features observed? both capture important interpretive context.
Limitations, sources of uncertainty and conditions affecting interpretation provides a free-text area for nuanced caveats.
How satisfied are you with the overall quality of this data set? (emotion rating) and Rate the overall completeness of the recorded information in this form (star rating) add subjective feedback dimensions.
Summary of findings is a mandatory free-text field with a detailed example placeholder demonstrating the expected level of detail. This is the key output of the entire form.
Conclusion or recommendation supports the analyst's interpretation.
Recommended next steps is a well-structured multi-select with conditional follow-ups for extended temperature ranges and complementary techniques.
Raw data export files (optional), Thermogram or mass-loss curve image and Supporting calculations, calibration certificates or notes (optional) provide attachment points for primary evidence.
Review status of this record tracks the document's lifecycle with appropriate follow-ups for reviewer identity and superseding records.
I confirm that the values recorded in this form reflect the runs performed and the data obtained as observed is a mandatory confirmation checkbox — a clear, proportionate attestation of data accuracy.
I understand this record documents test observations only and does not by itself certify material suitability for any particular application is a well-placed optional scope-limitation checkbox that sets appropriate expectations.
Name of person signing, Date of sign-off and Signature of analyst or authorised reviewer complete the record with formal sign-off.
This form is a technically rigorous, thoughtfully designed template for thermal analysis documentation. Its primary strengths are its logical workflow structure, extensive use of conditional logic to collect detail only where relevant, comprehensive capture of experiment-defining parameters, well-designed tables for tabulated data, and a strong emphasis on data quality self-assessment and transparency. The form's scope-limitation checkboxes and convention-specific reporting prompts reflect good technical awareness. Areas for potential consideration include the form's overall length, which may feel substantial for simple routine runs — some users might benefit from a streamlined version for common routine analyses. Additionally, the form includes some non-technical elements (cost fields, emotion and star ratings) that may be more or less relevant depending on the organisational context. Overall, the form provides an excellent foundation for building a reliable, traceable thermal analysis record system.
Mandatory Question Analysis for Thermal Analysis Record Form — DSC & TGA Test Report Template
Important Note:
This section explains why certain fields in this form are marked as required and provides general guidance on how these requirements may support the collection of complete, accurate and relevant information.
Required fields and information-collection obligations may vary depending on your industry, jurisdiction, business operations and intended use of the form. A field marked as required in this template does not necessarily mean that collecting the information is legally mandatory.
Please review each required field to determine whether it is necessary, appropriate and lawful for your particular purpose. Consider applicable privacy, data protection, consent and industry-specific requirements, and consult an appropriately qualified legal, privacy or compliance professional where necessary.
Please delete this section before publishing your form. See our Terms of Service for further information.
The form identifies 17 mandatory fields distributed across report identification, sample details, method selection, instrumentation, test conditions, results summary and sign-off. Below is an analysis of each mandatory field and its operational rationale.
Report or record reference number
Requiring a unique reference number ensures each thermal analysis record can be individually identified, indexed and retrieved within a document or record management system. This is a practical operational requirement for any environment where multiple test records are generated. The necessity of this field is well established for traceability purposes in most testing workflows.
Study or project title
Making the study or project title mandatory ensures every record carries sufficient contextual information for a reader to understand its scope without additional lookups. This supports efficient record retrieval and helps team members or clients orient themselves to the record. In contexts where all analyses are tied to a single project, the form creator may consider whether this could be pre-filled.
Date of analysis
Requiring the date of analysis anchors the record in time and supports correlation with instrument calibration status, sample condition and any concurrent events. For thermal analysis work, knowing when a run was performed is important for assessing whether the instrument state and sample handling conditions were current. This is a standard record-keeping practice.
Lead analyst or operator
Identifying the lead analyst is mandatory so that technical follow-up queries can be directed to the person who performed the work. This supports accountability and knowledge continuity, particularly in environments where multiple analysts share instruments. The field's necessity depends on the form creator's team structure, but it is a common and practical requirement for test records.
Sample ID
The sample ID is the primary link between thermal measurement data and a specific physical specimen. Requiring this field ensures complete data traceability and prevents ambiguity when results are reviewed or compared. In virtually any material testing workflow, sample identification is a core operational requirement for reliable record-keeping.
Technique(s) performed
Making technique selection mandatory ensures the record clearly states which thermal analysis methods were applied. Since DSC, TGA and other techniques produce fundamentally different data types, recording the technique is essential for interpreting the results section correctly. This requirement also drives the conditional follow-ups that capture technique-specific settings.
Primary objective of the analysis
Requiring a stated objective helps orient the results interpretation and ensures the record captures what the analysis was intended to address. This supports more focused review and helps determine whether the results meet the original purpose. The conditional follow-ups that trigger based on the selected objective collect relevant specification limits or reference values, further enhancing the record's utility.
Instrument reference/asset ID
Making the instrument reference mandatory links the record to a specific piece of equipment in the facility's asset register. This supports calibration tracking, instrument-specific troubleshooting and inter-instrument comparison. For any environment operating multiple instruments, this is a practical and commonly expected record-keeping requirement.
Sample mass used in the run (mg)
Requiring the measured sample mass ensures one of the most influential experimental parameters is recorded. Sample mass affects peak widths, measurement sensitivity and mass-loss percentages in TGA. For the results to be interpretable and reproducible, this value must be available. Its mandatory status is well justified for the form's intended purpose.
Heating rate (°C per minute)
Heating rate is a fundamental parameter that strongly influences observed peak temperatures, glass transition values and decomposition onset positions. Requiring this field ensures the record captures one of the primary conditions under which the thermal data was obtained. Without it, results cannot be reliably compared or reproduced.
Start temperature of the measured range (°C)
Requiring the start temperature defines the lower boundary of the measurement window. This is operationally important because any thermal events occurring below this temperature would not be detected. Recording this boundary helps reviewers understand the scope and limitations of the data.
End temperature of the measured range (°C)
Similarly, the end temperature defines the upper boundary. Together with the start temperature, these values establish whether the full thermal profile of the sample was captured. Both boundaries are necessary for interpreting what transitions and decomposition events could and could not have been observed.
Furnace/cell atmosphere during the measurement
The atmosphere during a thermal measurement profoundly affects decomposition behaviour, oxidation effects and mass-loss profiles. Requiring this field ensures the record documents one of the most critical environmental conditions of the test. For results to be meaningful and comparable across runs or laboratories, atmosphere must always be recorded.
Summary of findings
Requiring a summary of findings ensures the record contains a concise, human-readable statement of the key results. This is essential for readers who need to understand outcomes quickly without parsing raw data tables. The detailed example placeholder in the form guides users toward the expected level of specificity.
I confirm that the values recorded in this form reflect the runs performed and the data obtained as observed
This mandatory confirmation checkbox serves as an operational attestation by the analyst that the recorded values accurately represent what was measured. It is a proportionate and practical integrity check that supports confidence in the record without imposing complex verification requirements.
Name of person signing
Requiring the signatory's name ensures the record is formally attributable to a specific individual. This is a standard operational practice for test records and supports traceability and accountability. The field's necessity is well established in most documented testing workflows.
Date of sign-off
The sign-off date marks when the record was formally completed and confirmed. This may differ from the date of analysis — particularly for records that are reviewed or completed retrospectively. Requiring this date provides a clear record lifecycle timeline.
This form employs a well-balanced approach to required versus optional fields. The 17 mandatory fields are distributed across the form's full workflow — covering identification, sample tracking, method definition, instrumentation, core experimental parameters, results summary and formal sign-off. This distribution ensures that the most operationally essential information is always captured, while optional fields provide depth without imposing unnecessary burden.